| This error message will appear on screen when starting BPWin V4.78.0 with an autohandler:

The cause of this error is the Galil device not being present in Device Manager, which forces the use of the BPM driver (not recommended or preferred).
The solution is to install the Galil device in Device Manager, which then allows use of the API driver (recommended and preferred).
Procedure to install the Galil device:
Close BPWin.
Go to Start/Control Panel/Add Hardware.
Add Hardware Wizard will open.
Click Next. Wizard will search for a new device but not find one.
Check "Yes, I have already connected the hardware," Click Next.
Go to the bottom of the list and select "Add a new hardware device." Click Next.
Check "Install the hardware that I manually select from a list (Advanced)." Click Next.
Select "Show all devices." Click Next.
Under Manufacturer, select "Galil Motion Control, Inc."
Under Model, select "Galil DMC-10x0 Motion Controller." Click Next.
To install the hardware, click Next.
At the "Completing the Add Hardware Wizard" screen, click "View or change resources for this hardware (Advanced)."
Click "Set configuration manually."
Highlight "IRQ," and click "Change Setting."
Change the value from 03 to 10. Click OK.
Highlight "I/O Range" and click "Change Setting."
Ensure that the value is 0200 - 0203. Click OK.
Click OK. Windows message will ask to reboot the computer. Click Yes.
After reboot, go to Device Manager and ensure that the Galil device is present and does not have a yellow exclamation point or red "X."
Start BPWin.
|